Switching power supply 60Watt MDR60
DIN rail mounting
Regulated switching power supply, Short circuit and overload protected
Dimension: 40*90*100mm (Miniature single output)
Product-code: |
Power: |
Input voltage: |
MDR-60 12V |
60Watt 12VDC 5,00A |
85-264VAC, 120-370VDC |
MDR-60 24V |
60Watt 24VDC 2,50A |
85-264VAC, 120-370VDC |
Switching power supply 120Watt DR120
DIN rail mounting
Regulated switching power supply, Short circuit and overload protected
Dimension: 65,5 x 125,2 x 100 mm
Product-code: |
Power: |
Input voltage: |
DR120-12 / 10A |
120Watt 12VDC 10A |
88-132/176-264VAC selectable, 254-370VDC |
DR120-24 / 5A |
120Watt 24VDC 5A |
88-132/176-264VAC selectable, 254-370VDC |
Switching power supply 240Watt DRP240
DIN rail mounting
Regulated switching power supply, Short circuit and overload protected
With PFC according EN61000-3-2
Dimension: 125,5 x 125,2 x 100 mm
Product-code: |
Power: |
Input voltage: |
DRP240-24 / 10A |
240Watt 24VDC 10A |
85-264VAC, 120-370VDC |
DRP240-48 / 5A |
240Watt 48VDC 5A |
85-264VAC, 120-370VDC |
100W Single Output Switching Power Supply S-100F series
Features:
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 83KHz
2 years warranty
MODEL |
S-100F-5 |
S-100F-7.5 |
S-100F-12 |
S-100F-MODEL 15 |
S-100F-24 |
S-100F-48 |
OUTPUT |
DC VOLTAGE |
5V |
7.5V |
12V |
15V |
24V |
48V |
RATED CURRENT |
20A |
13.5A |
8.5A |
6.7A |
4.5A |
2.2A |
CURRENT RANGE |
0 ~ 20A |
0 ~ 13.5A |
0 ~ 8.5A |
0 ~ 6.7A |
0 ~ 4.5A |
0 ~ 2.2A |
RATED POWER |
100W |
101W |
102W |
100.5W |
108W |
105.6W |
RIPPLE & NOISE (max.) |
100mVp-p |
125mVp-p |
125mVp-p |
125mVp-p |
150mVp-p |
150mVp-p |
VOLTAGE ADJ. RANGE |
4.5 ~ 5.5V |
6.75 ~ 8.25V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
21.6 ~ 26.4V |
43.2 ~ 52.8V |
VOLTAGE TOLERANCE |
+-2.0% |
+-1.0% |
+-1.0% |
+-1.0% |
+-1.0% |
+-1.0% |
LINE REGULATION |
+-0.5% |
+-0.5% |
+-0.5% |
+-0.5% |
+-0.5% |
+-0.5% |
LOAD REGULATION |
+-1.0% |
+-0.5% |
+-0.5% |
+-0.5% |
+-0.5% |
+-0.5% |
SETUP, RISE TIME |
1000ms, 30ms at full load |
HOLD UP TIME (Typ.) |
20ms at full load |
INPUT |
VOLTAGE RANGE |
88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
76% |
78% |
80% |
81% |
83% |
84% |
AC CURRENT (Typ.) |
3.15A/115VAC 1.5A/230VAC |
INRUSH CURRENT (Typ.) |
COLD START 20A/115VAC 40A/230VAC |
LEAKAGE CURRENT |
<1mA / 240VAC |
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE |
5.75 ~ 6.75V |
8.63 ~ 10.13V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
55.2 ~ 64.8V |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60°C (Refer to output load derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-20 ~ +85°C , 10 ~ 95% RH |
TEMP. COEFFICIENT |
+-0.03%/°C (0 ~ 50°C) |
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC |
SAFETY STANDARDS |
CSA60950-1 (for 24V only), UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH |
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
OTHERS |
MTBF |
314.9K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION |
199*98*38mm (L*W*H) |
PACKING |
0.65Kg; 20pcs/14.2Kg/0.8CUFT |